Send Message
Zhenglan Cable Technology Co., Ltd
products
products
Home > products > Aluminum Conductor Steel Reinforced > 477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089

477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089

Product Details

Place of Origin: Henan, China

Brand Name: Zhenglan Cable

Certification: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007

Model Number: 477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors

Payment & Shipping Terms

Minimum Order Quantity: Negotiable

Price: 0.5-80USD/m

Packaging Details: Wooden drum, wood and steel drum,as customer's request

Delivery Time: 15 days

Payment Terms: T/T, L/C

Supply Ability: 10-30tons/day

Get Best Price
High Light:

acsr aluminum conductor steel reinforced

,

overhead line conductor

Material:
Aluminum Conductor Steel Reinforced
Aluminum:
Aluminum And Galvanized Steel Wire
Core:
Steel
Cable Drum Length:
Customized
Characted:
Bare Conductor
Total Area:
18.7~1211
Material:
Aluminum Conductor Steel Reinforced
Aluminum:
Aluminum And Galvanized Steel Wire
Core:
Steel
Cable Drum Length:
Customized
Characted:
Bare Conductor
Total Area:
18.7~1211
477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089

China Manufacturer 477 mcm ACSR Conductor Hot Sales Overhead Electric Transmission ACSR Line Conductors

 

 

APPLICATION

ACSR conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables.

 

STANDARD

Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.

 

CONSTRUCTION

ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.

By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.

 

477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089 TECHNICAL DATA

Numbers of Wires Modules of Elasticity Coeficient of linear Expansion
AL STEEL Kg/mm2 Lb/in2 1/Cº 1/Fº
6 1 81 11.5 x106 19.1 x10-6 10.6 x10-6
6 7 77 11.0 x106 19.8 x10-6 11.0 x10-6
12 7 107 15.2 x106 15.3 x10-6 8.5 x10-6
18 1 67 9.5 x106 21.2 x10-6 11.8 x10-6
24 7 74 10.5 x106 19.6 x10-6 10.9 x10-6
26 7 77 10.9 x106 18.9 x10-6 10.5 x10-6
28 7 79 11.2 x106 18.4 x10-6 10.2 x10-6
30 7 82 11.6 x106 17.8 x10-6 9.9 x10-6
30 19 80 11.4 x106 18.0 x10-6 10.0 x10-6
32 19 82 11.7 x106 17.5 x10-6 9.7 x10-6
54 7 70 9.9 x106 19.3 x10-6 10.7 x10-6
54 19 68 9.7 x106 19.4 x10-6 10.8 x10-6

 

477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089 CONSTRUCTION PARAMETERS

 

AMERICAN STANDARD ASTM B232-B232 M1999
Code Word Stranding Stranding Nominal Overall Diameter Mass Rated Strength
Aluminium Wires Steel Wires
Number Diameter Number Diameter
  mm   mm mm kg/Km kN
Raven 6/1 6 3.37 1 3.37 10.11 216.08 19.48
Minorca 12/7 12 2.44 7 2.44 12.22 411.18 50.26
Quail 6/1 6 3.78 1 3.78 11.35 272.04 23.58
Leghorn 12/7 12 2.69 7 2.69 13.46 499.28 60.5
Guinea 12/7 12 2.92 1 2.92 14.63 589.76 71.17
Pigeon 6/1 6 4.25 1 4.25 12.75 343.02 29.45
Dotterel 12/7 12 3.08 7 3.08 15.42 656.13 76.95
Dorking 12/7 12 3.2 7 3.2 16.03 707.92 83.18
Brahma 16/19 16 2.86 19 2.48 18.14 1003.91 126.33
Cochin 12/7 12 3.37 7 3.37 16.87 783.96 92.08
Penguin 6/1 6 4.77 1 4.77 14.3 432.76 37.14
Partidge 26/7 26 2.57 7 2 16.31 546.01 50.26
Waxwing 18/1 18 3.09 1 3.09 15.47 430.23 30.69
Ostrich 26/7 26 2.73 7 2.12 17.27 613.42 56.49
Oriole 30/7 30 2.69 1 2.69 18.82 783.37 76.95
Linnet 26/7 26 2.89 7 2.25 18.29 687.53 62.72
Widgeon 18/1 18 3.47 1 3.47 17.37 542.88 38.7
Lark 30/7 30 2.92 7 2.92 20.47 925.34 90.3
Ibis 26/7 26 3.14 7 2.44 19.89 812.54 72.51
Brant 24/7 24 3.27 1 2.18 19.61 761.05 64.94
Chickadee 18/1 18 3.77 1 3.77 18.87 641.4 44.04
Hen 30/7 30 3.2 7 3.2 22.43 1110.76 105.87
Hawk 26/7 26 3.44 7 2.67 21.79 975.19 86.74
Flicker 24/7 24 3.58 7 2.39 21.49 913.58 76.51
Pelican 18/1 18 4.14 1 4.14 20.68 769.83 52.49
Eagle 30/7 30 3.46 7 3.46 24.21 1295.74 123.66
Dove 26/7 26 3.72 7 2.89 23.55 1138.74 100.53
Parakeet 24/7 24 3.87 7 2.58 23.22 1065.67 88.07
Osprey 18/1 18 4.47 1 4.47 22.33 897.81 60.94
Teal 30/19 30 3.61 19 2.16 25.25 1396.79 133.45
WoodDuck 30/7 30 3.61 7 3.61 25.25 1408.54 128.55
Squab 26/7 26 3.87 7 2.84 24.54 1237.11 108.09
Peacock 24/7 24 4.03 7 2.69 24.21 1158.98 96.08
Egret 30/19 30 3.7 19 2.22 25.88 1469.11 140.12
Scoter 30/7 30 3.7 7 3.7 25.88 1480.87 135.23
Grosbeak 26/7 26 3.97 7 3.09 25.15 1300.95 112.09
Rook 24/7 24 4.14 7 2.76 24.82 1217.61 100.53
Swift 36/1 36 3.38 1 3.38 23.62 956.59 61.39
Kingbird 18/1 18 4.78 1 4.78 23.88 1026.68 69.84
Gannet 26/7 26 4.07 7 3.16 25.76 1363.45 117.43
Flamingo 24/7 24 4.23 7 2.82 25.4 1276.69 105.42
Redwing 30/19 30 3.92 19 2.35 27.46 1650.82 153.91
Starling 26/7 26 4.21 7 3.28 26.7 1463.9 126.33
Stilt 24/7 24 4.39 7 2.92 26.31 1370.6 113.43
Mallard 30/19 30 4.14 19 2.48 28.96 1836.24 170.81
Condor 54/7 54 3.08 7 3.08 27.74 1520.9 125.44
Term 45/7 45 3.38 7 2.25 27 1331.9 98.31
Rake 26/7 26 4.44 7 3.45 28.14 1626.56 140.12
Cukoo 24/7 24 4.62 7 3.08 27.74 1522.39 124.1
Coot 36/1 36 3.77 1 3.77 26.42 1195.89 74.73
Canary 54/7 54 3.28 7 3.28 29.51 1723.29 141.9
Ruddy 45/7 45 3.59 7 2.4 28.73 1507.51 108.54
Cardinal 54/7 54 3.58 7 3.38 30.38 1826.12 150.35
Rail 45/7 45 3.7 7 2.47 29.59 1598.28 115.21
Catbird 36/1 36 4.14 1 4.14 28.96 1434.59 88.07
Curlew 54/7 54 3.51 7 3.51 31.62 1977.76 162.8
Ortolan 45/7 45 3.85 7 2.57 30.78 1730.73 123.22
Tanager 36/1 36 4.3 1 4.3 30.12 1553.64 95.19
Finch 54/19 54 3.65 19 2.19 32.84 2128.07 173.92
Bluejay 45/7 45 4 7 2.66 31.98 1866.15 132.56
Grackle 54/19 54 3.77 19 2.27 33.99 2278.37 186.38
Bunting 45/7 45 4.14 7 2.76 33.07 1997.11 142.34
Pheasant 54/19 54 3.9 19 2.34 35.1 2431.65 193.94
Bittern 45/7 45 4.27 7 2.85 34.16 2131.05 151.68
Skylark 36/1 36 4.78 1 4.78 33.43 1913.77 117.43
Martin 54/19 54 4.02 19 2.41 36.17 2581.96 205.95
Dipper 45/7 45 4.5 7 2.93 35.2 2263.49 161.02
Piover 54/19 54 4.14 19 2.48 37.21 2735.24 218.41
Bobolink 45/7 45 4.53 7 3.02 36.25 2397.43 170.37
Parrot 54/19 54 4.25 19 2.55 38.23 2884.05 229.97
Nuthatch 45/7 45 4.65 7 3.1 37.24 2529.87 178.37
Falcon 54/19 54 4.36 19 2.62 39.24 3038.82 202.39
Lapwing 45/7 45 4.78 7 3.18 38.2 2663.81 187.71
Chukar 84/19 84 3.7 19 2.22 40.69 3083.47 226.86
Bluebird 84/19 84 4.07 19 2.44 44.75 3732.31 268.23
Kiwi 72/7 72 4.41 7 2.94 44.07 3424.26 221.52
Thrasher 76/19 76 4.43 19 2.07 45.77 3754.63 252.21

 

 

477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089 drawing

ACSR conductor structure

 

Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.
 
Our main products are
overhead power transmission use bare conductor(ACSR, AAC, etc)
1kv, 10kv, 35kv overhead power transmission use insulated conductor(single core covered cable, ABC cable)
STA/SWA armored or unarmored PVC/XLPE/PE insulated LV(low voltage) power cable
STA/SWA armored or unarmored XLPE insulated MV(medium voltage)power cable
450/750V instrument use control cable (shielded or unshielded)
300/300V, 300/500V, 450/750V fixed installation use building wire
477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089 1

477 Mcm ACSR Conductor / Overhead Electric Transmission ACSR Line Conductors BS50182/ASTMB232/232M/IEC61089 2

FAQ
Is your company a factory or a trade company?
Factory located in middle of China
How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
What is your MOQ?
Generally it is 5000m.
 

Why you choose us?

  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;