Send Message
Zhenglan Cable Technology Co., Ltd
Products
Products
Home > Products > Overhead Insulated Cable > 0.6 / 1KV Overhead Insulated Cable Phase Conductor AAC / XLPE / PE ASTM ABC

0.6 / 1KV Overhead Insulated Cable Phase Conductor AAC / XLPE / PE ASTM ABC

Product Details

Place of Origin: Henan, China

Brand Name: Zhenglan Cable

Certification: ISO 9001:2015,ISO 14001:2005; CCC

Model Number: 0.6/1KV aerial bundled cable

Payment & Shipping Terms

Minimum Order Quantity: 1000m

Price: Negotiable

Packaging Details: Wooden drum, iron wooden drum or as required

Delivery Time: 10 days

Payment Terms: L/C, T/T

Supply Ability: 15,000 KM/Year

Get Best Price
Highlight:

ASTM Overhead Insulated ABC Cable

,

Overhead Insulated Cable Phase Conductor

,

1KV Overhead Insulated ABC Cable

Insulation Material:
XLPE
Conductor Material:
AAC/AAAC/ACSR
Application:
Overhead
Quality:
100% Test
Standard:
ASTM B231 ASTMB 232 ASTM B399
Structure:
AL/XLPE+ACSR/XLPE
Voltage:
0.6/1KV
Port:
Qingdao Or Shanghai
Insulation Material:
XLPE
Conductor Material:
AAC/AAAC/ACSR
Application:
Overhead
Quality:
100% Test
Standard:
ASTM B231 ASTMB 232 ASTM B399
Structure:
AL/XLPE+ACSR/XLPE
Voltage:
0.6/1KV
Port:
Qingdao Or Shanghai
0.6 / 1KV Overhead Insulated Cable Phase Conductor AAC / XLPE / PE ASTM ABC

0.6/1KV Overhead Insulated Cable Phase Conductor AAC/XLPE/ PE+Neutral conductor AAAC/ACSR ASTM standards ABC cable

 

Conductor:


1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.

 

Insulation: PVC, XLPE, PE

 

Standards:
1. B-230 aluminum wire, 1350-h19 for electrical purposes.
2. B-231 aluminum conductors, concentric-lay-stranded.
3. B-232 aluminum conductors, concentric-lay-stranded, coated steel reinforced (ACSR).
4.B-399 concentric-lay stranded 6201-t81 aluminum alloy conductors.
5.B-498 zinc-coated steel core wire for aluminum conductors, steel reinforced (ACSR).
6. Duplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474


Rated voltage: 0.6/1kV


Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.
We can also manufacture ABC cable according to customer's special requirements.

 

Application:

 

ABC cable is used for aerial three phase power supply from the utility's lines to the consumer's servicehead

 

Below construction are also commonly used around the world.

A) Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

B) Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

3 cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.

It meets or exceeds the following specifications:

 

C ) Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

0.6/1KV Overhead ABC Cable AL 25mm 35mm 50mm 70mm 95mm 120mm Overhead Bare Aluminum Conductor​ parameters

 

SI. No. Description and Type of Cable Number of Wires Thickness of Approx overall Diameter Approx Weight of Cable Breaking Maximum D.C AC Current
XLPE Insulation Load of Resistance Rating
Phase Messenger Phase Messenger Messenger Ohms/Km Amps
mm mm mm Kg/KM KN (min) Phase Messenger In air at 40°C
With insulated messenger conductor
1 1 C x 16 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 20 165 7 1.91 1.38 72
2 3 C x 16 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 22 301 7 1.91 1.38 64
3 1 Cx25 mm2 + 25mm2(insulated) 7 7 1.2 1.2 22.4 195 7 1.2 1.38 99
4 3 C x 25 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 25 390 7 1.2 1.38 84
5 1 Cx35 mm2 + 25mm2(insulated) 7 7 1.2 1.2 27.3 227 7 0.868 1.38 120
6 3 C x 35 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 27.4 486 7 0.868 1.38 105
7 1 Cx35 mm2 + 35mm2(insulated) 7 7 1.2 1.2 28 259 10.1 0.868 0.986 120
8 3 C x 35 mm2 + 35 mm2 (insulated) 7 7 1.2 1.2 28.4 518 10.1 0.868 0.986 105
9 1 C x 50 mm2 + 35 mm2 (insulated) 7 7 1.5 1.2 29 317 10.1 0.641 0.986 150
10 3 C x 50 mm2 + 35 mm2 (insulated) 7 7 1.5 1.2 32.3 692 10.1 0.641 0.986 130
11 3Cx70 mm2 + 50 mm2 (insulated) 7 7 1.5 1.5 37.5 939 14 0.443 0.689 155
12 3 C x 70 mm2 + 70 mm2 (insulated) 7 7 1.5 1.5 39 1002 19.7 0.443 0.492 155
13 3 C x 95 mm2 + 70 mm2 (insulated) 19 7 1.5 1.5 42.7 1237 19.7 0.32 0.492 190
14 3 C x 120 mmz + 70 mm2 (insulated) 19 7 1.6 1.5 46 1482 19.7 0.253 0.492 220
15 3 C x 150 mm2 + 70 mm2 (insulated) 19 7 1.8 1.5 50 1791 19.7 0.206 0.492 250
With bare messenger conductor
1 1 C x 16 mm2 + 25 mm2 (bare) 7 7 1.2 / 18.5 137 7 1.91 1.38 72
2 3 C x 16 mm2 + 25 mm2 (bare) 7 7 1.2 / 19.3 272 7 1.91 1.38 64
3 1 C x 25 mm2 + 25 mm2 (bare) 7 7 1.2 / 19.5 167 7 1.2 1.38 99
4 3Cx25 mm2 + 25mm2(bare) 7 7 1.2 / 20.5 362 7 1.2 1.38 84
5 1 C x 35 mm2 + 25 mm2 (bare) 7 7 1.2 / 22 199 7 0.868 1.38 120
6 3 C x 35 mm2 + 25 mm2 (bare) 7 7 1.2 / 23.5 458 7 0.868 1.38 105
7 1 C x 35 mm2 + 35 mm2 (bare) 7 7 1.2 / 24.6 226 10.1 0.868 0.986 120
8 3Cx35 mm2 + 35 mm2 (bare) 7 7 1.2 / 25 485 10.1 0.868 0.986 105
9 1 C x 50 mm2 + 35 mm2 (bare) 7 7 1.5 / 26.6 284 10.1 0.641 0.986 150
10 3Cx50 mm2 + 35mm2(bare) 7 7 1.5 / 26.8 659 10.1 0.641 0.986 130
11 3 C x 70 mm2 + 50 mm2 (bare) 7 7 1.5 / 31.2 890 14 0.443 0.689 155
12 3Cx70 mm2 + 70mm2(bare) 7 7 1.5 / 34.4 946 19.7 0.443 0.492 155
13 3 C x 95 mm2 + 70 mm2 (bare) 19 7 1.5 / 36 1179 19.7 0.32 0.492 190
14 3 C x 120 mm2 + 70 mm2 (bare) 19 7 1.6 / 38 1425 19.7 0.253 0.492 220
15 3 C x 150 mm2 + 70 mm2 (bare) 19 7 1.8 / 40 1735 19.7__ 0.206 0.492 250 ―

 

Images

 

0.6 / 1KV Overhead Insulated Cable Phase Conductor AAC / XLPE / PE ASTM ABC 00.6 / 1KV Overhead Insulated Cable Phase Conductor AAC / XLPE / PE ASTM ABC 1

0.6 / 1KV Overhead Insulated Cable Phase Conductor AAC / XLPE / PE ASTM ABC 2

 

About Zhenglan Cable Technology Co., Ltd

 

Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.

 

0.6 / 1KV Overhead Insulated Cable Phase Conductor AAC / XLPE / PE ASTM ABC 3

 

FAQ
A: Is your company a factory or a trade company?
Factory, more than 20 years in China
B: How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
C: What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
D: What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
E: What is your MOQ?
Generally it is 5000m.