Product Details
Place of Origin: Henan, China
Brand Name: Zhenglan Cable
Certification: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Model Number: steel tape armoured 26/35KV XLPE 3X240mm2 mv cables, IEC60502-2
Payment & Shipping Terms
Minimum Order Quantity: 1500 meters
Price: Negotiable
Packaging Details: Wooden drum, wood and steel drum,as customer's request
Delivery Time: 10-20 DAYS
Payment Terms: L/C, T/T,, Western Union
Supply Ability: 1000km/M
Material: |
CU/AL |
Out Sheath Color: |
Black |
Core: |
Monoconductor |
Cable Drum Length: |
As Per Request |
Characted: |
Armored |
Specification: |
AL/CU/xlpe/cts/STA/SWA/pvc |
Name: |
26/35KV XLPE 3X240mm2 Mv Cables, IEC60502-2 |
Referece Standard: |
IEC60502-2 |
Port: |
Shanghai Or Qingdao |
Material: |
CU/AL |
Out Sheath Color: |
Black |
Core: |
Monoconductor |
Cable Drum Length: |
As Per Request |
Characted: |
Armored |
Specification: |
AL/CU/xlpe/cts/STA/SWA/pvc |
Name: |
26/35KV XLPE 3X240mm2 Mv Cables, IEC60502-2 |
Referece Standard: |
IEC60502-2 |
Port: |
Shanghai Or Qingdao |
Copper or aluminum conductor XLPE insulatedsteel tape armoured 26/35KV XLPE 3X240mm2 mv cables, IEC60502-2
APPLICATIONS:
is used in electric transmission and distribution system operating at rate voltage of 0.6/1, 6/10, 8.7/10, 18/30, 26/35KV.
STANDARD:
IEC 60502 Part 2(3.6/6KV to 18/30KV)
Cable Construction
We adopt highly specialized plant, state-of-the-art research facilities and meticulous quality control procedures that are required for the manufacturing of xlpe insulated cables for use up to 6KV and XLPE insulated cables for use at voltages up to 35 KV.
Conductors
Either aluminium or copper conductors are used. Conductors will be circular, compacted & stranded and shall comply with IEC 60228 class 2.
Conductor Screen
This will be an extruded layer of semi-conducting crosslinkable compound applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen. The triple extrusion is a single high precision operation that eliminates the possibility of any contamination between the layers which could create irregularities in the electrical field. By careful material selection and special attention to process parameters, we produce the insulation screen layers with the required degree of stripping force as stipulated by the applicable national or international standard.
Insulation
This will be an extruded layer of XLPE applied over conductor screen under triple extrusion process along with conductor screen and insulation screen.
Insulation Screen
This will be a layer of semi-conducting crosslinkable compound which will be applied by triple extrusion process over the insulation.
Metallic Screen
It will consist of a layer of copper tape applied helically with overlap over insulation screen. Other combinations of metallic screens as per customer ’s requirement can also be provided on request.
Laying-Up
In case of three core cables, the three cores are laid up with non-hygroscopic fillers like polypropylene(PP) fillers at interstices and a binder tape is applied with an overlap. These binder tapes can be of PVC or foamed Polyethylene.
Over Sheath
PVC, FR-PVC, PE or LSOH
Fire Performance on Cable Sheaths
Cables can also be supplied with special flame retardant PVC over sheaths to comply with the IEC 60332 standard. We can also supply cables with Low Smoke Halogen Free (LSZH) sheaths according to BS 7211 and BS 6724 standards or other equivalent international standards.
Copper or aluminum conductor XLPE insulatedsteel tape armoured 26/35KV XLPE 3X240mm2 mv cables reference technical parameters
Single Core 8.7/15KV Dimensional Data
Nom. Cross- Section Area |
Unarmoured Cables | Aluminium Wire Armoured Cables | |||||||||||
Nom. Insulation Thickness |
Copper Tape Thickness |
Copper Wire Screen Area* |
Nom. Sheath Thickness |
Approx. Overall Diameter |
Nom. Bedding Thickness |
Armour Wire Size |
Nom. Sheath Thickness |
Approx. Overall Diameter |
|||||
mm² | mm | mm | mm² | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
25 | 4.5 | 0.1 | 16 | 1.8 | 22 | 640 | 480 | 1.2 | 1.6 | 1.8 | 28 | 1020 | 860 |
35 | 4.5 | 0.1 | 16 | 1.8 | 23 | 760 | 540 | 1.2 | 1.6 | 1.9 | 29 | 1170 | 950 |
50 | 4.5 | 0.1 | 16 | 1.8 | 24 | 900 | 610 | 1.2 | 1.6 | 1.9 | 30 | 1340 | 1040 |
70 | 4.5 | 0.1 | 16 | 1.8 | 26 | 1140 | 710 | 1.2 | 1.6 | 2.0 | 32 | 1610 | 1190 |
95 | 4.5 | 0.1 | 16 | 1.8 | 27 | 1420 | 830 | 1.2 | 2.0 | 2.1 | 35 | 2020 | 1430 |
120 | 4.5 | 0.1 | 16 | 1.9 | 29 | 1700 | 950 | 1.2 | 2.0 | 2.1 | 36 | 2310 | 1570 |
150 | 4.5 | 0.1 | 25 | 1.9 | 31 | 1990 | 1070 | 1.2 | 2.0 | 2.2 | 38 | 2660 | 1740 |
185 | 4.5 | 0.1 | 25 | 2.0 | 32 | 2380 | 1230 | 1.2 | 2.0 | 2.2 | 39 | 3070 | 1920 |
240 | 4.5 | 0.1 | 25 | 2.1 | 35 | 3010 | 1490 | 1.2 | 2.0 | 2.3 | 42 | 3750 | 2240 |
300 | 4.5 | 0.1 | 25 | 2.1 | 37 | 3620 | 1720 | 1.3 | 2.5 | 2.4 | 46 | 4590 | 2690 |
400 | 4.5 | 0.1 | 35 | 2.2 | 41 | 4490 | 2070 | 1.3 | 2.5 | 2.5 | 49 | 5550 | 3120 |
500 | 4.5 | 0.1 | 35 | 2.3 | 43 | 5460 | 2460 | 1.3 | 2.5 | 2.6 | 52 | 6590 | 3600 |
630 | 4.5 | 0.1 | 35 | 2.4 | 48 | 6790 | 2590 | 1.4 | 2.5 | 2.7 | 57 | 8060 | 4110 |
Single Core 18/30KV Dimensional Data
Nom. Cross- Section Area |
Unarmoured Cables | Aluminium Wire Armoured Cables | |||||||||||
Nom. Insulation Thickness |
Copper Tape Thickness |
Copper Wire Screen Area* |
Nom. Sheath Thickness |
Approx. Overall Diameter |
Weight |
Nom. Bedding Thickness |
Armour Wire Size |
Nom. Sheath Thickness |
Approx. Overall Diameter |
Weight | |||
CU | AL | Cu | AL | ||||||||||
mm² | mm | mm | mm² | mm | mm | kg/km | mm | mm | mm | mm | kg/km | ||
50 | 8.0 | 0.1 | 16 | 2.0 | 31 | 1250 | 960 | 1.2 | 2.0 | 2.2 | 38 | 1910 | 1640 |
70 | 8.0 | 0.1 | 16 | 2.0 | 34 | 1510 | 1090 | 1.2 | 2.0 | 2.3 | 41 | 2240 | 1820 |
95 | 8.0 | 0.1 | 16 | 2.1 | 35 | 1830 | 1240 | 1.2 | 2.0 | 2.3 | 42 | 2570 | 1980 |
120 | 8.0 | 0.1 | 16 | 2.1 | 37 | 2110 | 1360 | 1.3 | 2.5 | 2.4 | 45 | 3060 | 2310 |
150 | 8.0 | 0.1 | 25 | 2.2 | 38 | 2420 | 1510 | 1.3 | 2.5 | 2.5 | 47 | 3430 | 2510 |
185 | 8.0 | 0.1 | 25 | 2.2 | 40 | 2830 | 1680 | 1.3 | 2.5 | 2.5 | 50 | 3890 | 2720 |
240 | 8.0 | 0.1 | 25 | 2.3 | 43 | 3500 | 1980 | 1.4 | 2.5 | 2.6 | 52 | 4630 | 3120 |
300 | 8.0 | 0.1 | 25 | 2.4 | 45 | 4150 | 2250 | 1.4 | 2.5 | 2.7 | 54 | 5330 | 3430 |
400 | 8.0 | 0.1 | 35 | 2.5 | 49 | 5070 | 2640 | 1.5 | 2.5 | 2.8 | 58 | 6360 | 3930 |
500 | 8.0 | 0.1 | 35 | 2.6 | 52 | 5945 | 2965 | 1.6 | 2.5 | 2.9 | 61 | 7670 | 4490 |
630 | 8.0 | 0.1 | 35 | 2.7 | 56 | 7445 | 3555 | 1.7 | 2.5 | 3.0 | 65 | 8870 | 5020 |
Copper or aluminum conductor XLPE insulatedsteel tape armoured 26/35KV XLPE 3X240mm2 mv cables IEC60502-2 images
Copper or aluminum conductor XLPE insulatedsteel tape armoured 26/35KV XLPE 3X240mm2 mv cables IEC60502-2 Package
Cable testing
About Zhenglan Cable Technology Co., Ltd
Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.
Why Choose Zhenglan Cable:
FAQ
1. Is your company a factory or a trade company?
Factory, more than 20 years in China
2. How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
3. What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
4. What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
5. What is your MOQ?
Generally for medinum voltage poer cable MOQ is 1000m.