Send Message
Products
Products
Home > Products > Bare Aluminum Conductor > Overhead Bare Conductor Wire AAC 35sqmm 7/2.59mm for Power Transmission

Overhead Bare Conductor Wire AAC 35sqmm 7/2.59mm for Power Transmission

Product Details

Place of Origin: Henan, China

Brand Name: Zhenglan Cable

Certification: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007

Model Number: Nominal Area: 35mm2 Overhead Bare Conductor Wire

Payment & Shipping Terms

Minimum Order Quantity: 1000meters

Price: 0.1-90USD/m

Packaging Details: Wooden drum, wood and steel drum,as customer's request

Delivery Time: 15 days

Payment Terms: L/C, T/T,, Western Union

Supply Ability: 15-30ton/day

Get Best Price
Highlight:

BS 215 BS Bare Aluminum Conductor

,

EN-50182 Overhead Bare Conductor

,

35sqmm Bare Aluminum Conductor

Material:
Aluminum Alloy
Out Sheath Color:
No
Country Of Oringinal:
China
Test:
100%
Characted:
Bare Conductor
Nearest Port:
Qingdao Port
Material:
Aluminum Alloy
Out Sheath Color:
No
Country Of Oringinal:
China
Test:
100%
Characted:
Bare Conductor
Nearest Port:
Qingdao Port
Overhead Bare Conductor Wire AAC 35sqmm 7/2.59mm for Power Transmission

Overhead Bare Conductor Wire AAC 35sqmm 7/2.59mm power transmission lines BS 215 BS EN-50182

 

APPLICATION:

Bare Aluminum conductors are used for transmission and distribution of electrical energy in overhead lines.
The most used metals for its manufacture are Aluminum 1350-H19, Aluminum alloy 6201-T81 and Aluminum reinforced with steel coated with Zinc or Aluminum.

 

STANDARD

ASTM B 231, BS EN-50182, CSA C 61089, AS/NZS 1531, DIN 48201, IEC 61089, GB/T 1179, JIS 3109

 

CONSTRUCTION

Aluminum 1350-H19 wires, concentrically stranded. 

 

 

AAC conductors have good mechanical properties and electrical conductivity, and are mainly used in power transmission lines, such as transmitting power from remote hydropower stations, thermal power plants or nuclear power plants to substations in the suburbs of cities.

 

Characteristics:

 

Code Number No. of Wires A2 Conductors Max. DC Resistance of Conductor at 20°C
Calculated Area Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm² - mm² mm mm kg/km daN Ω/km
16 7 18.4 1.83 5.49 50.4 5.43 1.7896
25 7 28.8 2.29 6.87 78.7 8.49 1.1453
40 7 46 2.89 8.67 125.9 13.58 0.7158
63 7 72.5 3.63 10.8 198.3 21.39 0.4545
100 19 115 2.78 13.9 316.3 33.95 0.2877
125 19 144 3.1 15.5 395.4 42.44 0.2302
160 19 184 3.51 17.55 506.1 54.32 0.1798
200 19 230 3.93 19.65 623.7 67.91 0.1439
250 19 288 4.39 21.95 790.8 84.68 0.1151
315 37 363 3.53 24.71 998.9 106.95 0.0916
400 37 460 3.98 27.86 1268.4 135.81 0.0721
450 37 518 4.22 29.54 1426.9 152.79 0.0641
500 37 575 4.45 31.15 1585.5 169.76 0.0577
560 61 645 3.67 33.03 1778.4 190.14 0.0516
630 61 725 3.89 35.01 2000.7 213.9 0.0458
710 61 817 4.13 37.17 2254.8 241.07 0.0407
800 61 921 4.38 39.42 2540.6 271.62 0.0361
900 91 1036 3.81 41.91 2861.1 305.58 0.0321
1000 91 1151 4.01 44.11 3179 339.53 0.0289
1120 91 1289 4.25 46.75 3560.5 380.27 0 0258

 

 

Code Name Total Area Stranding Conductor Nominal
diameter
Nominal Weight Rated Strength Maximum DC resistance
at 20 oC
AWG or MCM mm2 No / mm mm kg/km kN Ω /km
Akron 30.58 15.52 7 x 1.68 5.04 43 4.92 2.1588
Alton 48.69 24.71 7 x 2.12 6.36 68 7.83 1.3557
Ames 77.47 39.19 7 x 2.67 8.01 108 12.42 0.8547
Azusa 123.3 62.44 7 x 3.37 10.11 171 18.88 0.5365
Anaheim 155.4 78.55 7 x 3.78 11.34 216 23.75 0.4264
Amherst 195.7 99.30 7 x 4.25 12.75 272 30.03 0.3373
Alliance 246.9 125.10 7 x 4.77 14.31 343 37.83 0.2678
Butte 312.8 158.60 19 x 3.26 16.30 435 46.46 0.2112
Canton 394.5 199.90 19 x 3.66 18.30 548 58.56 0.1676
Cairo 465.4 236.40 19 x 3.98 19.90 649 69.25 0.1417
Darien 559.5 283.57 19 x 4.36 21.80 778 83.10 0.1181
Elgin 652.6 331.00 19 x 4.71 23.55 908 96.98 0.1012
Flint 740.8 374.50 37 x 3.59 25.13 1028 107.36 0.0894
Greeley 927.2 469.60 37 x 4.02 28.14 1289 134.62 0.0713

 

Product show

 

Overhead Bare Conductor Wire AAC 35sqmm 7/2.59mm for Power Transmission 0Overhead Bare Conductor Wire AAC 35sqmm 7/2.59mm for Power Transmission 1

About Us

 

We, Zhenglan Cable Technology Co., Ltd, are manufacturer of cable and wire with over 20years' experience.
Our factory workshop taking up about 60000SQM is located in Wuzhi County, Jiaozuo city, Henan province, in the middle of China.
Oversea sales center locates in Zhengzhou city, Henan, about 10minutes walk to Zhengdong Railway station, 45minutes' drive to Xinzheng International Airport.
Our main products are
  • overhead transmission line use bare conductor(ACSR, AAC, AAAC etc)
  • 1-35kv overhead transmission line use insulated conductor
  • power distribution use 0.6/1kv, 1.8/3kv PVC/XLPE/PE insulated LV(low voltage) power cable armored or unarmored
  • power distribution use 3.6/6kv, 6/10kv,8.7/10kv, 8.7/15kv, 12/20kv, 21/35kv, 26/35kv XLPE insulated MV(medium voltage) power cable armored or unarmored;
  • 300/300V, 300/500V, 450/750V cotrol cable, house wire

Why you choose us?

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.

Overhead Bare Conductor Wire AAC 35sqmm 7/2.59mm for Power Transmission 2

Contact at Any Time
Zhenglan Cable Technology Co., Ltd
Address::Floor 49, South Tower of Greenland Center, East Zhengzhou district, Zhengzhou, China
Fax: 86-371-61286032
Phone:86-371-61286031
Send
Privacy Policy | China Good Quality Aluminum Power Cable Supplier. Copyright © 2019-2024 Zhenglan Cable Technology Co., Ltd . All Rights Reserved.