Product Details
Place of Origin: Henan, China
Brand Name: Zhenglan Cable
Certification: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Model Number: Nominal Area:630mm2 AAC Overhead Bare Conductor Wire
Payment & Shipping Terms
Minimum Order Quantity: 300 meters
Packaging Details: Wooden drum, wood and steel drum,as customer's request
Delivery Time: 15 days
Payment Terms: L/C, T/T,
Material: |
AL |
Out Sheath Color: |
None |
Core: |
Normal Or Customized |
Cable Drum Length: |
Customized |
Characted: |
Bare Conductor |
Nominal Area: |
10~1500 |
Material: |
AL |
Out Sheath Color: |
None |
Core: |
Normal Or Customized |
Cable Drum Length: |
Customized |
Characted: |
Bare Conductor |
Nominal Area: |
10~1500 |
Overhead Bare Conductor Wire(Nominal Area:630mm2), AAC Conductor according to IEC 61089
AAC Conductor APPLICATION
AAC conductor is also known as aluminium stranded conductor. It is manufactured from electrolytically refined aluminium, with a minimum purity of 99.7%.
AAC Conductor STANDARD
Basic design to BS 215-1 / BS EN 50182 / IEC 61089 / ASTM B 231/B 231M / DIN 48201-5 standards.
Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
AAC Conductor CONSTRUCTION
Concentric lay stranded Aluminium Conductor (AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized. All aluminium conductors are made up of one or more strands of aluminium wire dep.
AAC Conductor ELECTRICAL PROPERTIES
density@20ºC | 2.703 kg/dm |
Temperature Coefficient@20°C | 0.00403 (°C) |
resistivity@20°C | 0.028264 |
linear Expansivity | 23 x10 (°C) |
Ambient Temperature | -5°C - 50°C |
Wind Pressure | 80 – 130kg/m |
Seismic Acceleration | 0.12 - 0.05g |
Isokeraunic level | 10 – 18 |
relative Humidity | 5 – 100% |
CONSTRUCTION PARAMETERS
• IEC 60189
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating* |
10 | 10 | 7/1.35 | 4.05 | 27.4 | 1.95 | 2.8633 | 62 |
16 | 16 | 7/1.71 | 5.13 | 43.8 | 3.04 | 1.7896 | 84 |
25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 | 110 |
40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 | 147 |
63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.39 | 0.4545 | 195 |
100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 | 259 |
125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.25 | 0.2302 | 297 |
160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 | 345 |
200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 | 396 |
250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 | 454 |
315 | 315 | 37/3.29 | 23.03 | 867.9 | 51.97 | 0.0916 | 522 |
400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 | 603 |
450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 | 647 |
500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 | 688 |
560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 | 736 |
630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 | 789 |
710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 | 845 |
800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 | 905 |
900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 | 967 |
1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 | 1026 |
1120* | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 | 1091 |
1250* | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 | 1157 |
1400* | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 | 1226 |
1500* | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 | 1270 |