Send Message
Zhenglan Cable Technology Co., Ltd
products
products
Home > products > Medium Voltage Power Cables > Mono Conductor 15kV XLPE/PVC insulation Medium Voltage Power Cables STA/SWA armour1x185sqmm IEC60502-2

Mono Conductor 15kV XLPE/PVC insulation Medium Voltage Power Cables STA/SWA armour1x185sqmm IEC60502-2

Product Details

Place of Origin: Henan, China

Brand Name: Zhenglan Cable

Certification: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007

Model Number: MONOCONDUCTOR 15 kV 100% XLPE insulated power cable 1x185sqmm IEC60502-2

Payment & Shipping Terms

Minimum Order Quantity: 3000m

Price: Negotiable

Packaging Details: Wooden drum, wood and steel drum,as customer's request

Delivery Time: 15 workdays for bulk order

Payment Terms: L/C, T/T,

Get Best Price
High Light:

Mono Conductor Medium Voltage Power Cables

,

1x185sqmm Medium Voltage Power Cables

,

15kV monopolar conductor cable

Material:
CU
Out Sheath Color:
Black
Core:
Monoconductor
Cable Drum Length:
As Per Request
Characted:
Unarmored
Specification:
Al/xlpe/cts/pvc
Name:
MONOCONDUCTOR 15 KV 100% XLPE Insulated Power Cable 1x185sqmm IEC60502-2
Referece Standard:
IEC60502-2
Material:
CU
Out Sheath Color:
Black
Core:
Monoconductor
Cable Drum Length:
As Per Request
Characted:
Unarmored
Specification:
Al/xlpe/cts/pvc
Name:
MONOCONDUCTOR 15 KV 100% XLPE Insulated Power Cable 1x185sqmm IEC60502-2
Referece Standard:
IEC60502-2
Mono Conductor 15kV XLPE/PVC insulation Medium Voltage Power Cables STA/SWA armour1x185sqmm IEC60502-2

MONOCONDUCTOR 15 kV 100% XLPE insulated power cable 1x185sqmm IEC60502-2

 

APPLICATIONS:

MONOCONDUCTOR 15 kV 100% XLPE insulated power cable 1x185sqmm IEC60502-2 are designed for distribution of electrical power with nominal voltage Uo/U ranging from 12/20(24)KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

 

STANDARD:

IEC 60502 Part 2(3.6/6KV to 18/30KV)

 

Cable Construction

We adopt highly specialized plant, state-of-the-art research facilities and meticulous quality control procedures that are required for the manufacturing of xlpe insulated cables for use up to 6KV and XLPE insulated cables for use at voltages up to 35 KV. 

 

Conductors

Either aluminium or copper conductors are used. Conductors will be circular, compacted & stranded and shall comply with IEC 60228 class 2. 

 

Conductor Screen

This will be an extruded layer of semi-conducting crosslinkable compound applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen. The triple extrusion is a single high precision operation that eliminates the possibility of any contamination between the layers which could create irregularities in the electrical field. By careful material selection and special attention to process parameters, we produce the insulation screen layers with the required degree of stripping force as stipulated by the applicable national or international standard.

 

Insulation

This will be an extruded layer of XLPE applied over conductor screen under triple extrusion process along with conductor screen and insulation screen.

 

Insulation Screen

This will be a layer of semi-conducting crosslinkable compound which will be applied by triple extrusion process over the insulation.

 

Metallic Screen

It will consist of a layer of copper tape applied helically with overlap over insulation screen. Other combinations of metallic screens as per customer ’s requirement can also be provided on request.

 

Laying-Up

In case of three core cables, the three cores are laid up with non-hygroscopic fillers like polypropylene(PP) fillers at interstices and a binder tape is applied with an overlap. These binder tapes can be of PVC or foamed Polyethylene.

 

Over Sheath

An extruded layer is applied over the armour in case of armoured cables and over laid up cores in case of unarmoured cables. Outer sheath material can be either PVC, PE, HDPE or MDPE. our

medium voltage cables are normally supplied with red PVC over sheaths complying with BS 6622 or IEC 60502. Other colors may be provided to suit a range of installation considerations such as the effect of UV radiations and differing soil compositions. Anti-termite formulations can also be supplied in addition to graphite-coated over sheaths where on-site testing of the sheath is required.

 

Fire Performance on Cable Sheaths

Cables can also be supplied with special flame retardant PVC over sheaths to comply with the IEC 60332 standard. We can also supply cables with Low Smoke Halogen Free (LSZH) sheaths according to BS 7211 and BS 6724 standards or other equivalent international standards.

 

 

Technical parameters

Single Core 8.7/15KV Dimensional Data

Nom.

Cross-

Section

Area

  Unarmoured Cables Aluminium Wire Armoured Cables

Nom.

Insulation

Thickness

Copper

Tape

Thickness

Copper

Wire

Screen

Area*

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

 

Nom.

Bedding

Thickness

Armour

Wire

Size

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

 
       
mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km
25 4.5 0.1 16 1.8 22 640 480 1.2 1.6 1.8 28 1020 860
35 4.5 0.1 16 1.8 23 760 540 1.2 1.6 1.9 29 1170 950
50 4.5 0.1 16 1.8 24 900 610 1.2 1.6 1.9 30 1340 1040
70 4.5 0.1 16 1.8 26 1140 710 1.2 1.6 2.0 32 1610 1190
95 4.5 0.1 16 1.8 27 1420 830 1.2 2.0 2.1 35 2020 1430
120 4.5 0.1 16 1.9 29 1700 950 1.2 2.0 2.1 36 2310 1570
150 4.5 0.1 25 1.9 31 1990 1070 1.2 2.0 2.2 38 2660 1740
185 4.5 0.1 25 2.0 32 2380 1230 1.2 2.0 2.2 39 3070 1920
240 4.5 0.1 25 2.1 35 3010 1490 1.2 2.0 2.3 42 3750 2240
300 4.5 0.1 25 2.1 37 3620 1720 1.3 2.5 2.4 46 4590 2690
400 4.5 0.1 35 2.2 41 4490 2070 1.3 2.5 2.5 49 5550 3120
500 4.5 0.1 35 2.3 43 5460 2460 1.3 2.5 2.6 52 6590 3600
630 4.5 0.1 35 2.4 48 6790 2590 1.4 2.5 2.7 57 8060 4110

 

Single Core 18/30KV Dimensional Data

Nom.

Cross-

Section

Area

  Unarmoured Cables Aluminium Wire Armoured Cables
 

Nom.

Insulation

Thickness

Copper

Tape

Thickness

Copper

Wire

Screen

Area*

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

Weight

Nom.

Bedding

Thickness

Armour

Wire

Size

Nom.

Sheath

Thickness

Approx.

Overall

Diameter

Weight
            CU AL         Cu AL
mm² mm mm mm² mm mm kg/km mm mm mm mm kg/km
50 8.0 0.1 16 2.0 31 1250 960 1.2 2.0 2.2 38 1910 1640
70 8.0 0.1 16 2.0 34 1510 1090 1.2 2.0 2.3 41 2240 1820
95 8.0 0.1 16 2.1 35 1830 1240 1.2 2.0 2.3 42 2570 1980
120 8.0 0.1 16 2.1 37 2110 1360 1.3 2.5 2.4 45 3060 2310
150 8.0 0.1 25 2.2 38 2420 1510 1.3 2.5 2.5 47 3430 2510
185 8.0 0.1 25 2.2 40 2830 1680 1.3 2.5 2.5 50 3890 2720
240 8.0 0.1 25 2.3 43 3500 1980 1.4 2.5 2.6 52 4630 3120
300 8.0 0.1 25 2.4 45 4150 2250 1.4 2.5 2.7 54 5330 3430
400 8.0 0.1 35 2.5 49 5070 2640 1.5 2.5 2.8 58 6360 3930
500 8.0 0.1 35 2.6 52 5945 2965 1.6 2.5 2.9 61 7670 4490
630 8.0 0.1 35 2.7 56 7445 3555 1.7 2.5 3.0 65 8870 5020

 

MONOCONDUCTOR 15 kV 100% XLPE insulated power cable 1x185sqmm IEC60502-2  images

single core MV cable 1x150

 

Package

Mono Conductor 15kV XLPE/PVC insulation Medium Voltage Power Cables STA/SWA armour1x185sqmm IEC60502-2 1

 

Cable testing 

Mono Conductor 15kV XLPE/PVC insulation Medium Voltage Power Cables STA/SWA armour1x185sqmm IEC60502-2 2
 


About Zhenglan Cable Technology Co., Ltd

Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.

 

 

Why Choose Zhenglan Cable:

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.

FAQ
1. Is your company a factory or a trade company?
Factory, more than 20 years in China

2. How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.

 

3. What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.

4. What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.

 

5. What is your MOQ?
Generally for medinum voltage poer cable MOQ is 1000m.