Product Details
Place of Origin: Henan, China
Brand Name: Zhenglan Cable
Certification: ISO 9001:2015,ISO 14001:2005; CCC
Model Number: 0.6/1kV,2 Core 4 Core 3 Core Al/XLPE Insulated Cable overhead insulated cable IEC60502-1
Payment & Shipping Terms
Minimum Order Quantity: Negotiable
Price: Negotiable
Packaging Details: Wooden drum, iron wooden drum or as required
Delivery Time: 5-10 days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 15,000 KM/Year
Insulation Material: |
XLPE Or PVC |
Conductor Material: |
Aluminum |
Application: |
Overhead |
Quality: |
100% Test |
Standard: |
GB/T 12527-2008, IEC60502-1 |
Structure: |
AL/XLPE |
Voltage: |
0.6/1KV |
Port: |
Qingdao Or Shanghai |
Origin: |
China |
Insulation Material: |
XLPE Or PVC |
Conductor Material: |
Aluminum |
Application: |
Overhead |
Quality: |
100% Test |
Standard: |
GB/T 12527-2008, IEC60502-1 |
Structure: |
AL/XLPE |
Voltage: |
0.6/1KV |
Port: |
Qingdao Or Shanghai |
Origin: |
China |
0.6/1KV PVC XLPE Overhead Insulated Cable 2 Core 4 Core 3 Core Overhea IEC60502-1
Conductor:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.
Insulation: PVC, XLPE, PE
Standards:
GB/T 12527-2008, IEC60502,
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.
We can also manufacture ABC cable according to customer's special requirements.
Application:
APPLICATION: Used primarily for overhead secondary distribution lines.
Below construction are also commonly used around the world.
A) Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.
B) Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .
3 cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
It meets or exceeds the following specifications:
C ) Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.
600 V,1Cx35mm2 Al/XLPE Covered Line Wire Aluminum Conductor IEC60502-1 parameters
Nominal cross sectional area(mm²) | Wire Minimum no. | Conductor diameter(mm) |
Nominal Insulation thickness (mm) |
Single wire average nominal diameter maximum value(mm) | Max. Conductor resistance at 20 ℃(Ω/km) | Min insulation resistance at rated working temper(MΩ*km | Single wire tensile strength(N) | |||
Aluminum | Aluminum alloy | 70℃ | 90℃ | Aluminum | Aluminum alloy | |||||
10 | 6 | 3.8 | 1.0 | 6.5 | 3.08 | 3.574 | 0.0067 | 0.67 | 1650 | 2514 |
16 | 6 | 3.8 | 1.2 | 8.0 | 1.91 | 2.217 | 0.0065 | 0.65 | 2517 | 4022 |
25 | 6 | 6.0 | 1.2 | 9.4 | 1.20 | 1.393 | 0.0054 | 0.54 | 3762 | 6284 |
35 | 6 | 7.0 | 1.4 | 11.0 | 0.868 | 1.007 | 0.0054 | 0.54 | 5177 | 8800 |
50 | 6 | 8.4 | 1.4 | 12.3 | 0.641 | 0.744 | 0.0046 | 0.46 | 7011 | 12569 |
70 | 12 | 10.0 | 1.4 | 14.1 | 0.443 | 0.514 | 0.0040 | 0.40 | 10354 | 17596 |
95 | 15 | 11.6 | 1.6 | 16.5 | 0.320 | 0.371 | 0.0039 | 0.39 | 13727 | 23880 |
120 | 15 | 13.0 | 1.6 | 18.1 | 0.253 | 0.294 | 0.0035 | 0.35 | 17339 | 30164 |
150 | 15 | 14.6 | 1.8 | 20.2 | 0.206 | 0.239 | 0.0035 | 0.35 | 21033 | 37706 |
185 | 30 | 16.2 | 2.0 | 22.5 | 0.164 | 0.190 | 0.0035 | 0.35 | 26732 | 46503 |
240 | 30 | 18.4 | 2.2 | 25.6 | 0.125 | 0.145 | 0.0034 | 0.34 | 34679 | 60329 |
300 | 30 | 20.8 | 2.2 | 27.2 | 0.100 | 0.116 | 0.0033 | 0.33 | 43349 | 75411 |
400 | 53 | 23.2 | 2.2 | 30.7 | 0.0778 | 0.0904 | 0.0032 | 0.32 | 55707 | 100548 |
About Zhenglan Cable Technology Co., Ltd
Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.
FAQ
Is your company a factory or a trade company?
Factory, more than 20 years in China
How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
What is your MOQ?
Generally it is 5000m.