Send Message
Home ProductsOverhead Insulated Cable

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2

Certification
China Zhenglan Cable Technology Co., Ltd certification
China Zhenglan Cable Technology Co., Ltd certification
Customer Reviews
The quality of the cables is very good, Strong factory strength!

—— Lewis

Very happy cooperation, strong supply capacity!

—— Diana

They are real cable factory.

—— Clicerio

I'm Online Chat Now

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2
0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2 0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2

Large Image :  0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2

Product Details:
Place of Origin: Henan, China
Brand Name: Zhenglan Cable
Certification: ISO 9001:2015,ISO 14001:2005; CCC
Model Number: 0.6/1kv aerial bundle cable AAC/XLPE phase cable with bare AAAC neutral cable 3Cx25 mm2 + 25mm2(bare) IS:14255 -1995
Payment & Shipping Terms:
Minimum Order Quantity: 1000m
Price: Negotiable
Packaging Details: Wooden drum, iron wooden drum or as required
Delivery Time: 10 days
Payment Terms: L/C, T/T
Supply Ability: 15,000 KM/Year

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2

Description
Insulation Material: XLPE Phase Cable: Aluminum
Neutral Cable: Aluminum Alloy Application: Overhead Line Use, Aerial Electrical Line Use
Standard: GB/T 12527-2008, IEC60502-1, NFC33209 Structure: AAC/XLPE+NA AAAC
Voltage: 0.6/1KV Port: Qingdao Or Shanghai
High Light:

0.6/1kv Aerial Bunched Conductor

,

3Cx25Mm2 Aerial Bunched Conductor

,

AAC XLPE abc bundle conductor

0.6/1kv aerial bundle cable AAC/XLPE phase cable with bare AAAC neutral cable 3Cx25 mm2 + 25mm2(bare) IS:14255 -1995

Conductor:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.

Insulation: PVC, XLPE, PE

 

Standards:
GB/T 12527-2008, IEC60502-1, 
IS:14255-1995
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.
We can also manufacture ABC cable according to customer's special requirements.

 

Application:

APPLICATION: Used primarily for overhead secondary distribution lines.

 

Below construction are also commonly used around the world.

A) Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

B) Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

3 cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.

It meets or exceeds the following specifications:

 

C ) Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

0.6/1kv aerial bundle cable AAC/XLPE phase cable with bare AAAC neutral cable 3Cx25 mm2 + 25mm2(bare) IS:14255 -1995 parameters

 

SI. No. Description and Type of Cable Number of Wires Thickness of Approx overall Diameter Approx Weight of Cable Breaking Maximum D.C AC Current
      XLPE Insulation     Load of Resistance Rating
    Phase Messenger Phase Messenger     Messenger Ohms/Km Amps
        mm mm mm Kg/KM KN (min) Phase Messenger In air at 40°C
With insulated messenger conductor
1 1 C x 16 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 20 165 7 1.91 1.38 72
2 3 C x 16 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 22 301 7 1.91 1.38 64
3 1 Cx25 mm2 + 25mm2(insulated) 7 7 1.2 1.2 22.4 195 7 1.2 1.38 99
4 3 C x 25 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 25 390 7 1.2 1.38 84
5 1 Cx35 mm2 + 25mm2(insulated) 7 7 1.2 1.2 27.3 227 7 0.868 1.38 120
6 3 C x 35 mm2 + 25 mm2 (insulated) 7 7 1.2 1.2 27.4 486 7 0.868 1.38 105
7 1 Cx35 mm2 + 35mm2(insulated) 7 7 1.2 1.2 28 259 10.1 0.868 0.986 120
8 3 C x 35 mm2 + 35 mm2 (insulated) 7 7 1.2 1.2 28.4 518 10.1 0.868 0.986 105
9 1 C x 50 mm2 + 35 mm2 (insulated) 7 7 1.5 1.2 29 317 10.1 0.641 0.986 150
10 3 C x 50 mm2 + 35 mm2 (insulated) 7 7 1.5 1.2 32.3 692 10.1 0.641 0.986 130
11 3Cx70 mm2 + 50 mm2 (insulated) 7 7 1.5 1.5 37.5 939 14 0.443 0.689 155
12 3 C x 70 mm2 + 70 mm2 (insulated) 7 7 1.5 1.5 39 1002 19.7 0.443 0.492 155
13 3 C x 95 mm2 + 70 mm2 (insulated) 19 7 1.5 1.5 42.7 1237 19.7 0.32 0.492 190
14 3 C x 120 mmz + 70 mm2 (insulated) 19 7 1.6 1.5 46 1482 19.7 0.253 0.492 220
15 3 C x 150 mm2 + 70 mm2 (insulated) 19 7 1.8 1.5 50 1791 19.7 0.206 0.492 250
With bare messenger conductor
1 1 C x 16 mm2 + 25 mm2 (bare) 7 7 1.2 / 18.5 137 7 1.91 1.38 72
2 3 C x 16 mm2 + 25 mm2 (bare) 7 7 1.2 / 19.3 272 7 1.91 1.38 64
3 1 C x 25 mm2 + 25 mm2 (bare) 7 7 1.2 / 19.5 167 7 1.2 1.38 99
4 3Cx25 mm2 + 25mm2(bare) 7 7 1.2 / 20.5 362 7 1.2 1.38 84
5 1 C x 35 mm2 + 25 mm2 (bare) 7 7 1.2 / 22 199 7 0.868 1.38 120
6 3 C x 35 mm2 + 25 mm2 (bare) 7 7 1.2 / 23.5 458 7 0.868 1.38 105
7 1 C x 35 mm2 + 35 mm2 (bare) 7 7 1.2 / 24.6 226 10.1 0.868 0.986 120
8 3Cx35 mm2 + 35 mm2 (bare) 7 7 1.2 / 25 485 10.1 0.868 0.986 105
9 1 C x 50 mm2 + 35 mm2 (bare) 7 7 1.5 / 26.6 284 10.1 0.641 0.986 150
10 3Cx50 mm2 + 35mm2(bare) 7 7 1.5 / 26.8 659 10.1 0.641 0.986 130
11 3 C x 70 mm2 + 50 mm2 (bare) 7 7 1.5 / 31.2 890 14 0.443 0.689 155
12 3Cx70 mm2 + 70mm2(bare) 7 7 1.5 / 34.4 946 19.7 0.443 0.492 155
13 3 C x 95 mm2 + 70 mm2 (bare) 19 7 1.5 / 36 1179 19.7 0.32 0.492 190
14 3 C x 120 mm2 + 70 mm2 (bare) 19 7 1.6 / 38 1425 19.7 0.253 0.492 220
15 3 C x 150 mm2 + 70 mm2 (bare) 19 7 1.8 / 40 1735 19.7 0.206 0.492 250

 

Other cross-sections can be offered upon request.

Stranded & Compacted Aluminium Phase Conductor,and Stranded Messenger Conductor with All Aluminium Alloy. Phase Conductor is insulated with XLPE Compound, Messenger is either insulated or bare with lighting Conductor
of 16 mm2. Referred Specification IS:14255 -1995
SI.No. Description and Type of Cable Number of Wires Thickness of XLPE Insulation Approx overall Diameter Approx Weight of Cable Breaking Load of Messenger Maximum D.C Resistance AC Current Rating
Phase Messenger Phase Messenger Phase Messenger Amps
mm mm mm Kg/KM KN (min) Ohms/Km In air at 40°C
With insulated messenger conductor
1 3 C x 16 mm2 + 25 mm2 (insulated)+16 mm2 7 7 1.2 1.2 23.5 369 7 1.91 1.38 62
2 3 Cx25 mm2 + 25 mm2 (insulated)+16 mm2 7 7 1.2 1.2 25 457 7 1.2 1.38 82
3 3Cx35 mm2 + 25mm2(insulated)+16mm2 7 7 1.2 1.2 27.5 554 7 0.868 1.38 103
4 3 C x 35 mm2 + 35 mm2 (insulated)+16 mm2 7 7 1.2 1.2 28.4 586 10.1 0.868 0.986 103
5 3Cx50 mm2 + 35mm2(insulated)+16mm2 7 7 1.5 1.2 32.5 760 10.1 0.641 0.986 127
6 3Cx70 mm2 + 50mm2(insulated)+16mm2 7 7 1.5 1.5 37.5 1007 14 0.443 0.689 154
7 3Cx70 mm2 + 70mm2(insulated)+16mm2 7 7 1.5 1.5 39.5 1070 19.7 0.443 0.492 154
8 3 C x 95 mm2 + 70 mm2 (insulated)+16 mm2 19 7 1.5 1.5 42.5 1304 19.7 0.32 0.492 188
9 3 C x 120 mm2 + 70 mm2 (insulated)+16 mm2 19 7 1.6 1.5 46.8 1550 19.7 0.253 0.492 218
10 3 C x 150 mm2 + 70 mm2 (insulated)+16 mm2 19 7 1.8 1.5 50.8 1860 19.7 0.206 0.492 248
With bare messenger conductor
1 3 C x 16 mm2 + 25 mm2 (bare)+16 mm2 7 7 1.2 / 19.5 340 7 1.91 1.38 62
2 3 C x 25 mm2 + 25 mm2 (bare)+16 mm2 7 7 1.2 / 20.5 429 7 1.2 1.38 82
3 3 C x 35 mm2 + 25 mm2 (bare)+16 mm2 7 7 1.2 / 23.5 526 7 0.868 1.38 103
4 3 C x 35 mm2 + 35 mm2 (bare)+16 mm2 7 7 1.2 / 25 553 10.1 0.868 0.986 103
5 3 C x 50 mm2 + 35 mm2 (bare)+16 mm2 7 7 1.5 / 26.8 727 10.1 0.641 0.986 127
6 3 C x 70 mm2 + 50 mm2 (bare)+16 mm2 7 7 1.5 / 31.5 958 14 0.443 0.689 154
7 3 C x 70 mm2 + 70 mm2 (bare)+16 mm2 7 7 1.5 / 34.5 1013 19.7 0.443 0.492 154
8 3 C x 95 mm2 + 70 mm2 (bare)+16 mm2 19 7 1.5 / 37 1248 19.7 0.32 0.492 188
9 3 C x 120 mm2 + 70 mm2 (bare)+16 mm2 19 7 1.6 / 39 1493 19.7 0.253 0.492 218
10 3 C x 150 mm2 + 70 mm2 (bare)+16 mm2 19 7 1.8 / 40 1803 19.7 0.206 0.492 248

 

 

0.6/1kv aerial bundle cable AAC/XLPE phase cable with bare AAAC neutral cable 3Cx25 mm2 + 25mm2(bare) IS:14255 -1995 images

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2 0

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2 1

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2 2

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2 3

 

 

0.6/1kv aerial bunched conductor AAC/XLPE Phase Cable With Bare AAAC 3Cx25 Mm2 + 25mm2 4

 

About Zhenglan Cable Technology Co., Ltd

Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.

 

FAQ
Is your company a factory or a trade company?
Factory, more than 20 years in China
How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
What is your MOQ?
Generally it is 5000m.

 

 

Contact Details
Zhenglan Cable Technology Co., Ltd

Contact Person: Miss. Linda Yang

Tel: +86 16638166831

Fax: 86-371-61286032

Send your inquiry directly to us (0 / 3000)