Send Message
Zhenglan Cable Technology Co., Ltd
products
products
Home > products > Overhead Insulated Cable > 0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209

0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209

Product Details

Place of Origin: Henan, China

Brand Name: Zhenglan Cable

Certification: ISO 9001:2015,ISO 14001:2005; CCC

Model Number: 0.6/1kv aerial bundle cable for overhead electrical power line use 3x25+1x54.6+1x16mm2

Payment & Shipping Terms

Minimum Order Quantity: 1000m

Price: Negotiable

Packaging Details: Wooden drum, iron wooden drum or as required

Delivery Time: 10 days

Payment Terms: L/C, T/T

Supply Ability: 15,000 KM/Year

Get Best Price
High Light:

0.6/1kv Aerial Bundle Cable

,

NFC33209 Aerial Bundle Cable

,

0.6/1kv aerial bunched cables

Insulation Material:
XLPE
Phase Cable:
Aluminum
Neutral Cable:
Aluminum Alloy
Application:
Overhead Line Use, Aerial Electrical Line Use
Standard:
GB/T 12527-2008, IEC60502-1, NFC33209
Structure:
AAC/XLPE+NA AAAC/XLPE+AAC/XLPE
Voltage:
0.6/1KV
Port:
Qingdao Or Shanghai
Insulation Material:
XLPE
Phase Cable:
Aluminum
Neutral Cable:
Aluminum Alloy
Application:
Overhead Line Use, Aerial Electrical Line Use
Standard:
GB/T 12527-2008, IEC60502-1, NFC33209
Structure:
AAC/XLPE+NA AAAC/XLPE+AAC/XLPE
Voltage:
0.6/1KV
Port:
Qingdao Or Shanghai
0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209

0.6/1kv aerial bundle cable for overhead electrical power line use 3x25+1x54.6+1x16mm2

Conductor:
1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2. Aluminum Conductors, Concentric-Lay-Stranded.
3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. Concentric-Lay-Stranded 6201-T81 Conductors.

Insulation: PVC, XLPE, PE

 

Standards:
GB/T 12527-2008, IEC60502-1, 
IS:14255-1995
Rated voltage: 0.6/1kV
Relative manufacturing standards: IEC61089, ASTM B231, ASTM B232, BS215, DIN48201, DIN48204.
We can also manufacture ABC cable according to customer's special requirements.

 

Application:

APPLICATION: Used primarily for overhead secondary distribution lines.

 

Below construction are also commonly used around the world.

A) Duplex Service Drop
Applications:To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting . For service at 600 volts or lower at a conductor temperature of 75 maximum.

B) Triplex Service Drop
Applications: To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation .

3 cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.

It meets or exceeds the following specifications:

 

C ) Quadruplex Service Drop
Applications: Used to supply 3 phase power , usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made . To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

 

0.6/1kv aerial bundle cable for overhead electrical power line use 3x25+1x54.6+1x16mm2  parameters

NUMBER OF CORES X NOMINAL CROSS SECTION OVERAL DIAMETER WEIGHT MAXIMUM CONDUCTOR RESISTANCE MINIMUM BREAKING LOAD CURRENT RATING
NO.×MM² MM KG/KM Ω/KM KN A
2x10 RM 12.8 93 3.080 1.5 38
4x10 RM 15.4 183 3.080 1.5 38
2x16 RM 14.8 129 1.910 2.3 72
4x16 RM 17.8 257 1.910 2.3 72
2x25 RM 18.0 202 1.200 3.8 107
4x25 RM 21.7 404 1.200 3.8 107
2x35 RM 20.8 269 0.868 5.2 132
4x35 RM 25.1 539 0.868 5.2 132
2x50 RM 23.4 352 0.641 7.6 165
1x54.6 RM + 3x25 RM 21.7 507 0.630/1.200 3.8 107
1x54.6 RM + 3x25 RM + 1x16 RM 24.3 573 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 2x16 RM 29.7 639 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x25 RM + 3x16 RM 31.1 705 0.630/1.200/1.910 3.8/2.3 107/72
1x54.6 RM + 3x35 RM 25.1 615 0.630/0.868 5.2 132
1x54.6 RM + 3x35 RM + 1x16 RM 28.1 680 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 2x16 RM 34.3 748 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 3x16 RM 35.9 814 0.630/0.868/1.910 5.2/2.3 132/72
1x54.6 RM + 3x35 RM + 1x25 RM 28.1 714 0.630/0.868/1.200 5.2/3.8 132/107
1x54.6 RM + 3x50 RM 28.2 741 0.630/0.641 7.6 165
1x54.6 RM + 3x50 RM + 1x16 RM 31.6 806 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 2x16 RM 38.6 875 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 3x16 RM 40.4 940 0.630/0.641/1.910 7.6/2.3 165/72
1x54.6 RM + 3x50 RM + 1x25 RM 31.6 841 0.630/0.641/1.200 7.6/3.8 165/107
1x54.6 RM + 3x70 RM 33.0 950 0.630/0.443 10.2 205
1x54.6 RM + 3x70 RM + 1x16 RM 37.0 1014 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 2x16 RM 45.2 1083 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 3x16 RM 47.3 1148 0.630/0.443/1.910 10.2/2.3 205/72
1x54.6 RM + 3x70 RM + 1x25 RM 37.0 1048 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 2x25 RM 45.2 1150 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x70 RM + 3x25 RM 47.3 1250 0.630/0.443/1.200 10.2/3.8 205/107
1x54.6 RM + 3x95 RM 37.4 1176 0.630/0.320 13.5 240
1x54.6 RM + 3x95 RM + 1x16 RM 41.9 1243 0.630/0.320/1.910 13.5/2.3 240/72

Other cross-sections can be offered upon request.

 

 

Other cross-sections can be offered upon request.

Stranded & Compacted Aluminium Phase Conductor,and Stranded Messenger Conductor with All Aluminium Alloy. Phase Conductor is insulated with XLPE Compound, Messenger is either insulated or bare with lighting Conductor
of 16 mm2. Referred Specification IS:14255 -1995
SI.No. Description and Type of Cable Number of Wires Thickness of XLPE Insulation Approx overall Diameter Approx Weight of Cable Breaking Load of Messenger Maximum D.C Resistance AC Current Rating
Phase Messenger Phase Messenger Phase Messenger Amps
mm mm mm Kg/KM KN (min) Ohms/Km In air at 40°C
With insulated messenger conductor
1 3 C x 16 mm2 + 25 mm2 (insulated)+16 mm2 7 7 1.2 1.2 23.5 369 7 1.91 1.38 62
2 3 Cx25 mm2 + 25 mm2 (insulated)+16 mm2 7 7 1.2 1.2 25 457 7 1.2 1.38 82
3 3Cx35 mm2 + 25mm2(insulated)+16mm2 7 7 1.2 1.2 27.5 554 7 0.868 1.38 103
4 3 C x 35 mm2 + 35 mm2 (insulated)+16 mm2 7 7 1.2 1.2 28.4 586 10.1 0.868 0.986 103
5 3Cx50 mm2 + 35mm2(insulated)+16mm2 7 7 1.5 1.2 32.5 760 10.1 0.641 0.986 127
6 3Cx70 mm2 + 50mm2(insulated)+16mm2 7 7 1.5 1.5 37.5 1007 14 0.443 0.689 154
7 3Cx70 mm2 + 70mm2(insulated)+16mm2 7 7 1.5 1.5 39.5 1070 19.7 0.443 0.492 154
8 3 C x 95 mm2 + 70 mm2 (insulated)+16 mm2 19 7 1.5 1.5 42.5 1304 19.7 0.32 0.492 188
9 3 C x 120 mm2 + 70 mm2 (insulated)+16 mm2 19 7 1.6 1.5 46.8 1550 19.7 0.253 0.492 218
10 3 C x 150 mm2 + 70 mm2 (insulated)+16 mm2 19 7 1.8 1.5 50.8 1860 19.7 0.206 0.492 248
With bare messenger conductor
1 3 C x 16 mm2 + 25 mm2 (bare)+16 mm2 7 7 1.2 / 19.5 340 7 1.91 1.38 62
2 3 C x 25 mm2 + 25 mm2 (bare)+16 mm2 7 7 1.2 / 20.5 429 7 1.2 1.38 82
3 3 C x 35 mm2 + 25 mm2 (bare)+16 mm2 7 7 1.2 / 23.5 526 7 0.868 1.38 103
4 3 C x 35 mm2 + 35 mm2 (bare)+16 mm2 7 7 1.2 / 25 553 10.1 0.868 0.986 103
5 3 C x 50 mm2 + 35 mm2 (bare)+16 mm2 7 7 1.5 / 26.8 727 10.1 0.641 0.986 127
6 3 C x 70 mm2 + 50 mm2 (bare)+16 mm2 7 7 1.5 / 31.5 958 14 0.443 0.689 154
7 3 C x 70 mm2 + 70 mm2 (bare)+16 mm2 7 7 1.5 / 34.5 1013 19.7 0.443 0.492 154
8 3 C x 95 mm2 + 70 mm2 (bare)+16 mm2 19 7 1.5 / 37 1248 19.7 0.32 0.492 188
9 3 C x 120 mm2 + 70 mm2 (bare)+16 mm2 19 7 1.6 / 39 1493 19.7 0.253 0.492 218
10 3 C x 150 mm2 + 70 mm2 (bare)+16 mm2 19 7 1.8 / 40 1803 19.7 0.206 0.492 248

 

 

0.6/1kv aerial bundle cable AAC/XLPE phase cable with bare AAAC neutral cable 3Cx25 mm2 + 25mm2(bare) IS:14255 -1995 images

0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209 0

0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209 1

0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209 2

0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209 3

 

 

0.6/1kv Aerial Bundle Cable For Overhead Electrical Power Line 3x25+1x54.6+1x16mm2 NFC33209 4

 

About Zhenglan Cable Technology Co., Ltd

Zhenglan Cable Technology CO., Ltd.,formerly known as HENAN Zhengzhou Cable Co., Ltd., is one of the large scale backbone enterprises in China's wire and cable industry. The company's registered capital is about 4 million 6 thousand yuan and its headquarter is located in 49 floor of the South Tower of the Greenland Center of Zhengzhou high railway station (Petronas Twin Towers). The factory is located in the Zhengzhou cable science and Technology Industrial Park of the Wuzhi industrial area. It is a modern industrial park integrating advanced research and development technology and production technology.

 

FAQ
Is your company a factory or a trade company?
Factory, more than 20 years in China
How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.
What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.
What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.
What is your MOQ?
Generally it is 5000m.