Product Details
Place of Origin: Henan, China
Brand Name: Zhenglan Cable
Certification: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Model Number: AC conductor 35/6.2mm2 Aluminum conductor steel reinforced Gost 839
Payment & Shipping Terms
Minimum Order Quantity: 300 meters
Packaging Details: Wooden drum, wood and steel drum,as customer's request
Delivery Time: 15 days
Payment Terms: L/C, T/T,
Material: |
AL& Steel |
Core: |
Customized |
Cable Mark: |
/ |
Cable Drum Length: |
Customized |
Characted: |
Bare Conductor |
Armoured: |
No |
Material: |
AL& Steel |
Core: |
Customized |
Cable Mark: |
/ |
Cable Drum Length: |
Customized |
Characted: |
Bare Conductor |
Armoured: |
No |
AC conductor 35/6.2mm2 Aluminum conductor steel reinforced Gost 839
Overhead ACSR Conductors APPLICATION
A wire consisting of a steel core made of galvanized steel wires of normal strength and aluminum wires. widely used in the creation of overhead high-voltage power lines on supports with long spans, operating in difficult environmental conditions with the presence of wind, icing and snow sticking to the wires.
Overhead ACSR Conductors STANDARD
Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110/Gost 839 standards.
Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
The product is used where the air serves as an insulator, and only on land:
Power lines.
Substation.
Power supply to switchgears.
Electrified transport lines.
Circuits that distribute power to electrical appliances and machines.
Overhead ACSR Conductors ELECTRICAL PROPERTIES
density@20ºC | Aluminium: 2.703 kg/dm |
Galvanised Steel: 7.80 kg/dm | |
Temperature Coefficient@20°C | Aluminium: 0.00403 (°C) |
resistivity@20°C | Aluminium: Should not exceed 0.028264 |
linear Expansivity
|
Aluminium: 23 x10 (°C) |
Galvanised Steel: 11.5 x10 (1/°C) |
Overhead ACSR Conductors SERVICE CONDITIONS
Ambient Temperature | -5°C - 50°C |
Wind Pressure | 80 – 130kg/m |
Seismic Acceleration | 0.12 - 0.05g |
Isokeraunic level | 10 – 18 |
relative Humidity | 5 – 100% |
Overhead ACSR Conductors TECHNICAL DATA
Numbers of Wires | Modules of Elasticity | Coeficient of linear Expansion | |||
AL | STEEL | Kg/mm2 | Lb/in2 | 1/Cº | 1/Fº |
6 | 1 | 81 | 11.5 x106 | 19.1 x10-6 | 10.6 x10-6 |
6 | 7 | 77 | 11.0 x106 | 19.8 x10-6 | 11.0 x10-6 |
12 | 7 | 107 | 15.2 x106 | 15.3 x10-6 | 8.5 x10-6 |
18 | 1 | 67 | 9.5 x106 | 21.2 x10-6 | 11.8 x10-6 |
24 | 7 | 74 | 10.5 x106 | 19.6 x10-6 | 10.9 x10-6 |
26 | 7 | 77 | 10.9 x106 | 18.9 x10-6 | 10.5 x10-6 |
28 | 7 | 79 | 11.2 x106 | 18.4 x10-6 | 10.2 x10-6 |
30 | 7 | 82 | 11.6 x106 | 17.8 x10-6 | 9.9 x10-6 |
30 | 19 | 80 | 11.4 x106 | 18.0 x10-6 | 10.0 x10-6 |
32 | 19 | 82 | 11.7 x106 | 17.5 x10-6 | 9.7 x10-6 |
54 | 7 | 70 | 9.9 x106 | 19.3 x10-6 | 10.7 x10-6 |
54 | 19 | 68 | 9.7 x106 | 19.4 x10-6 | 10.8 x10-6 |
AC conductor 35/6.2mm2 Aluminum conductor steel reinforced Gost 839 CONSTRUCTION PARAMETERS
Code | Area | No. of Wires | Wire Diameter | Diameter | Mass per Unit | Rated Strength | DC Resistance | |||||
AL | Steel | Total | AL | Steel | AL | Steel | Core | Cond. | Length | |||
mm2 | 2 mm | 2 mm | mm | mm | mm | mm | kg/km | kN | Q/km | |||
35/6.2 | 36.9 | 6.2 | 41.2 | 6 | 1 | 2.8 | 2.8 | 2.8 | 8.4 | 148 | 13.2 | 0.7821 |