0.6/1KV Low Smoke Zero Halogen Cable/ 3+1 Cores Power Cable (Unarmoured) , PVC Insulated Cable (CU/PVC/LSZH/NYY/N2XY)

Product Details

Place of Origin: Henan, China

Brand Name: Zhenglan cable

Certification: 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007

Model Number: 0.6/1KV Low Smoke Zero Halogen Cable

Payment & Shipping Terms

Minimum Order Quantity: 300 meters

Packaging Details: Wooden drum, wood and steel drum,as customer's request

Delivery Time: 12 days

Payment Terms: L/C, T/T,

Get Best Price
High Light:

fire resistant low smoke cables

,

low smoke halogen free cable

Material:
Cu
Application:
Power Station
Insulation:
PVC (Low Smoke Zero Halogen Material)
Color:
Red Or Black
Out Sheath Color:
Black Or Customized
Core:
3+1
Cable Drum Length:
Customized
Material:
Cu
Application:
Power Station
Insulation:
PVC (Low Smoke Zero Halogen Material)
Color:
Red Or Black
Out Sheath Color:
Black Or Customized
Core:
3+1
Cable Drum Length:
Customized
0.6/1KV Low Smoke Zero Halogen Cable/ 3+1 Cores Power Cable (Unarmoured) , PVC Insulated Cable (CU/PVC/LSZH/NYY/N2XY)

0.6/1KV Low Smoke Zero Halogen Cable/ 3+1 Cores Power Cable (Unarmoured) , PVC Insulated Cable (CU/PVC/LSZH/NYY/N2XY)

 

Description:
0.6/1KV PVC Insulated Cables
IEC60502,IEC60228,GB/T 12706.1-2008
CE,CCC,KEMA,ISO

 

Construction:

Conductors:Copper or Aluminium conductor, round standed or Shaped, Class 2 to IEC 60228, BS EN 60228. For smaller sizes, a solid round conductor, Class 1 as per IEC 60228, BS EN 60228 can also be supplied upon request.

 

Noted: Insulation color as per standards or customer requirement.

 

Application:

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

Standard:

Basic design to IEC 60502-1, IEC 60228,BS EN 60228

China: GB/T 12706.2-2008

Other standards such as BS7870,DIN and ICEA upon request

 

Certificates:
CE, ROHS,KEMA and more others at request

 

Insulation:

PVC Insulation material and thickness shall be as per IEC 60502-1 and BS 6346. PVC material shall be Type A as per IEC 60502-1 or TI1 as per BS EN 50363.PVC Insulation material as per SASO 1694 rated for 85°C continuous operation is also available upon special request.

 

Colour Code Colour Code (1):

1 Core: Red or Black;   2 Cores: Red, Black;    3 Cores: Red, Yellow, Blue;   4 Cores: Red, Yellow, Blue, Black;     5 Cores: Red, Yellow, Blue, Black, Green;  Above 5 Cores: Black Cores with White numerals

 

Assembly /Inner Sheath:

Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non- armoured cables, this layer may be omitted

Armour: Aluminum/Galvanized Steel Wires applied helically over the bedding as per IEC 60502 or as per BS 5467, BS 6346. Single core cables shall be Aluminium wire armour. Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502.

 

Outer Sheath: Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSF, CPE are available on request.

 

Fire Performance of Cable Sheaths: Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, can also supply cables with Low Smoke Halogen Free (LSHF) material according to IEC 60502-1, BS 7211, BS 6724 or other equivalent standards.

 

Cable Parameters:

Three cores+1 (unarmoured)

Nominal

Cross

Section

Diameter of Conductor

(Approx.)

Nominal

Insulation

Thickness

Nominal

PVC Sheath

Thickness

Overall

Diameter

(Approx.)

Weight

of Cable

(Approx.)

mm² mm mm mm mm Kg/Km
3x1.5 1.38 0.8 1.8 13 230
3x2.5 1.76 0.8 1.8 13.5 280
3x4 2.25 1.0 1.8 15.5 380
3x6 2.76 1.0 1.8 17.0 470
3x10 4.0 1.0 1.8 18.5 630
3x16 5.0 1.0 1.8 21.0 880
3x25 6.3 1.2 1.8 24.5 1280
3x35 7.4 1.2 1.8 27 .0.0 1660
3x50 8.8 1.4 1.8 30.0 2110
3x70 10.6 1.4 1.9 35.0 2980
3x95 12.4 1.6 2.0 40.0 3930
3x120 14.0 1.6 2.1 43.0 4780
3x150 15.5 1.8 2.3 48.0 5880
3x185 17.4 2.0 2.4 52.0 7230
3x240 20.3 2.2 2.6 59.0 9390
3x300 22.7 2.4 2.7 65.0 11620
3x400 25.4 2.6 3.0 72.0 14730

 

0.6/1KV Low Smoke Zero Halogen Cable/ 3+1 Cores Power Cable (Unarmoured) , PVC Insulated Cable (CU/PVC/LSZH/NYY/N2XY) 0

 

0.6/1KV Low Smoke Zero Halogen Cable/ 3+1 Cores Power Cable (Unarmoured) , PVC Insulated Cable (CU/PVC/LSZH/NYY/N2XY) 1

 

Why Choose Zhenglan Cable:

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.