How to choose cable's nominal cross sectional area?

1. Select the cable cross-sectional area according to the long-term allowable current-carrying capacity 1.1 In order to ensure safety and the service life of the cable, the temperature of the cable after power-on should not exceed the specified long-term allowable working temperature. The temperature is 70 degrees for polyvinyl chloride insulated cables and 90 degrees for XLPE insulated cables. According to this principle , It's very simple to look up the table and choose the cable. 1.2 Examples: A certain factory has a transformer capacity of 2500KVa and uses 10KV power supply. If XLPE insulated cables are used to lay in the bridge, what is the cross-sectional area of ​​the cable? Step 1: Calculate the rated current 2500/10.5/1.732=137A Step 2: Check the cable selection manual to know YJV-8.7/10KV-3X25 current carrying capacity is 120A YJV-8.7/10KV-3X35 current carrying capacity is 140A Step 3: Choose YJV-8.7/10KV-3X35 with a cable carrying capacity greater than 137A, which can theoretically meet the requirements. Note: This method does not consider the requirements of dynamic stability and thermal stability. 2. Choose the cable cross-sectional area according to the economic current density Simply understand the economic current density. The cross-sectional area of ​​the cable affects the line investment and power loss. In order to save investment, it is hoped that the cable cross-sectional area should be smaller; in order to reduce the power loss, it is hoped that the cable cross-sectional area should be larger; based on the above considerations, determine a reasonable one The cross-sectional area of ​​the cable is called the economic cross-sectional area, and the corresponding current density is called the economic current density. 3. Select the cable cross-sectional area according to the voltage drop of the power grid When we use the first and second methods to select the cross-sectional area of ​​the cable, if the cable is very long, a certain voltage drop will occur during operation and startup, and the voltage on the device side will be below a certain range, which will cause the device to heat up. 4. Select the cross-sectional area of ​​the cable according to the thermal stability coefficient (that is, select the cross-sectional area of ​​the cable according to the short-circuit current) 4.1 When the 0.4KV cable is protected by an air switch, the general cable can meet the thermal stability requirements, so there is no need to verify it according to this method. 4.2 For cables above 6KV, after selecting the cross-sectional area of ​​the cable using the above method, you must verify whether it meets the thermal stability requirements according to the following formula. If it does not meet the requirements, choose a larger cross-sectional area. Formula: Smin=Id×√Ti/C Among them, Ti is the breaking time of the circuit breaker, which is 0.25S, C is the thermal stability coefficient of the cable, which is 80, and Id is the three-phase short-circuit current value of the system. For example: when the system short-circuit current is 18KA, how to choose the cable cross-sectional area. Smin=18000×√0.25/80=112.5 Conclusion: If the system short-circuit current reaches 18KA, even if the rated current of the equipment is smaller, the cable cross-sectional area should not be less than 120mm2.
2021/10/12

How to choose low voltage distribution conductor?

1. Copper core or aluminum core can be used for cables and wires, and copper core cables or wires should be used for civil buildings; Copper core cables or wires shall be used in the following places: 1) Flammable and explosive places; 2) Important public buildings and residential buildings; 3) Especially humid places and places with corrosion to aluminum; 4) Places where people gather more; 5) Important reference room, computer room and important warehouse; 6) Mobile equipment or places with severe vibration; 7) Other places with special regulations. 2 the insulation type of conductor shall be selected according to the laying mode and environmental conditions, and shall comply with the following provisions: 1) In general engineering, under indoor normal conditions, PVC insulated and PVC sheathed cables or PVC insulated wires can be selected; If possible, XLPE insulated power cables and wires can be selected; 2) The selection of power supply lines for fire fighting equipment shall comply with the provisions of section 13.10 of this specification; 3) For buildings with high fire protection requirements such as class I high-rise buildings and important public places, flame retardant low smoke halogen-free XLPE insulated power cables and wires or smoke-free halogen-free power cables and wires shall be adopted. 3. The insulated conductor shall meet the requirements of working voltage. The indoor laying of plastic insulated wire shall not be less than 0.45/0.75kv, and the power cable shall not be less than 0.6/lkv;
2021/09/11
14 15 16 17 18 19 20 21 22 23
Privacy Policy | China Good Quality Aluminum Power Cable Supplier. Copyright © 2019-2025 Zhenglan Cable Technology Co., Ltd . All Rights Reserved.